| Table 2: Typical Physical Properties |
|
Typical Physical Properties*
|
|
Property |
Test Method |
Typical Values |
|
Dimensional Stability
|
ASTM D 2126
|
2% linear change
|
|
Compressive Strength
|
ASTM D 1621
|
20 psi***
|
|
Water Absorption
|
ASTM C 209
|
<1% by volume
|
|
Moisture Vapor Transmission
|
ASTM
E 96
|
<One (1) Perm
|
|
Product Density
|
ASTM D 1622
|
Nominal 2.0 lbs./cu. ft.
|
|
Flame Spread (foam core)
|
ASTM E 84
|
25** (based on full 10 min. test)
|
|
Service Temperature
|
-
|
-100 deg. F to 250 deg. F Max.
|
* The Physical Properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. This data is offered as a service to our customers and is subject to change. All information can be confirmed by contacting Koppers.
** These numerical ratings, as determined by ASTM Test Method E-84, are not intended to reflect hazards presented by these or any other material under actual fire conditions.
***Also available in 25psi.